VOC Emission Monitoring, Emission Monitoring Systems, VOC Control, Environmental Compliance, FID, Flame Ionization Detector, FTIR, Fourier Transform Infrared Spectroscopy, FTA, Flame Thermal Analyzer, Industrial Emissions, Air Quality, Sustainability, EMS, HMI, DEC, Dynamic Environmental Corporation (DEC), DEC IMPIANTI, DEC HOLDING, DEC SERVICE, DEC ENGINEERING, DEC AUTOMATION, DEC LAB, DEC ANALYTICS, DEC Group

VOC Industrial Emission Monitoring Systems
DEC.EMS™

Volatile Organic Compounds (VOCs) are a significant contributor to air pollution and climate change. Effective emission control systems are crucial for industries that generate VOC emissions. To ensure compliance with environmental regulations and optimize system performance, robust emission monitoring is essential.

Emission Monitoring Systems (EMS) are technologies that measure and track the pollutants released by industrial activities. These systems are crucial for ensuring compliance with environmental regulations and minimizing the environmental impact of industrial operations. By continuously monitoring emissions, industries can identify and address areas for improvement, leading to a reduction in harmful pollutants released into the atmosphere.

VOC Emission Monitoring, Emission Monitoring Systems, VOC Control, Environmental Compliance, FID, Flame Ionization Detector, FTIR, Fourier Transform Infrared Spectroscopy, FTA, Flame Thermal Analyzer, Industrial Emissions, Air Quality, Sustainability, EMS, HMI, DEC, Dynamic Environmental Corporation (DEC), DEC IMPIANTI, DEC HOLDING, DEC SERVICE, DEC ENGINEERING, DEC AUTOMATION, DEC LAB, DEC ANALYTICS, DEC Group

DEC.EMS™ is a suite of Emission Monitoring Systems designed to meet the diverse needs of different industries. It incorporates different analytical (ATX™) technologies, including Flame Ionization Detectors (FIDs), Flame Thermal Analyzers (FTAs), and Fourier Transform Infrared Spectroscopy (FTIR), to accurately measure VOC concentrations in flue gas.

The VOC emission analytical results are typically expressed as TVOCs (Total Volatile Organic Compounds).

DEC.HMI™, a user-friendly interface, is integrated with each DEC.EMS™ configuration to enhance operational efficiency. It provides real-time data visualization, alarm functionalities, diagnostic and basic data logging capabilities.

VOC Emission Monitoring, Emission Monitoring Systems, VOC Control, Environmental Compliance, FID, Flame Ionization Detector, FTIR, Fourier Transform Infrared Spectroscopy, FTA, Flame Thermal Analyzer, Industrial Emissions, Air Quality, Sustainability, EMS, HMI, DEC, Dynamic Environmental Corporation (DEC), DEC IMPIANTI, DEC HOLDING, DEC SERVICE, DEC ENGINEERING, DEC AUTOMATION, DEC LAB, DEC ANALYTICS, DEC Group

EMS_FID-SL™ • single-line FID monitoring

The EMS_FID-SL™ system utilizes an ATX module, where a single point of analysis draws a sample directly from the flue gas stack (FGS).

  • DEC.HMI™ of the VOC emission control system records the trends, with limited data logging and reporting capabilities;
  • standard ATX config: FID | Flame Ionization Detector (optional compliance: EN 15267 | QAL 1 - EN 14181);
  • optional ATX config: FTA | Flame Thermal Analyzer module (for US market only);
  • relatively simple and cost-effective instrument to install and maintain;
  • provides real-time data on TVOC concentrations;
  • may not meet the stringent requirements of some regulatory Agencies.
  • EMS_FID-ML™ • multi-line FID monitoring

    The EMS_FID-ML™ system utilizes an ATX module, where a sampling system alternates different lines to draw samples directly from the inlet duct of the VOC emission control system and from its flue gas stack (FGS).

  • DEC.HMI™ of the VOC emission control system records the trends, with limited data logging and reporting capabilities;
  • standard ATX config: FID | Flame Ionization Detector (when used in single line sampling conditions, optional compliance: EN 15267 | QAL 1 - EN 14181);
  • optional ATX config: FTA | Flame Thermal Analyzer (available for US market only);
  • optional ATX config: multi-sampling configuration;
  • relatively simple and cost-effective instrument to install and maintain;
  • provides real-time data on TVOC concentrations;
  • offers improved data quality compared to single-line systems, calculating the average VOC emission control system abatment efficiency;
  • may not meet the stringent requirements of some regulatory Agencies.
  • EMS_CEMS™ • Continuous Emission Monitoring System

    The EMS_CEMS™ is a sophisticated analytical unit that continuously measures and records the concentration of pollutants in flue gases. The system provides important information for the environmental and economic operation of production facilities, a scalable unit to support from the one stack (FGS) installations up to multi-block plants, up to numerous measuring points. The measurement is handled using certified ATX module(s):

  • Data Acquisition and Handling System (DAHS): dedicated hardware (stand-alone PLC module) collects, processes, and stores data in a secure database (optional compliance: EN 17255);
  • standard ATX config: FID | Flame Ionization Detector (EN 15267 | QAL 1 - EN 14181 compliant);
  • optional ATX config: FTIR | Fourier Transform Infrared Spectroscopy, for extended monitoring HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CH4, TVOC, H2O, CO2, O2, etc.);
  • additional set of dedicated instruments and/or sensors (e.g. flow-rate, pressure, temperature, humidity, etc.);
  • higher initial investment and ongoing maintenance costs;
  • requires skilled personnel for operation and maintenance;
  • typically meets the stringent requirements of most environmental regulatory Angencies;
  • system can be interfaced with the Environmental Agency for autonomous direct monitoring of the VOC emission control system.
  • built on innovation,
    inspired by passion

    DEC HOLDING, DEC, Dynamic Environmental Corporation (DEC), DEC IMPIANTI, DEC SERVICE, DEC ENGINEERING, DEC AUTOMATION, DEC LAB, DEC ANALYTICS, DEC Group